Santa Fe Compact70 vs AprilAire E050W
Compact70 documents more removal at both shared rating points. E050W has a lower nominal cabinet height, with feet excluded. Neither observation decides the installed fit.
| Compare the details | Santa Fe Compact70 | AprilAire E050W |
|---|---|---|
| Cabinet H × W × LConfirm feet, collars and service access. | 12 × 12 × 21 in | 10 × 12 × 25 in |
| Drainage | gravity; external pump optional | gravity by default; optional 4856 pump |
| Capacity at 65°F / 60% RH | 43.7 pints/dayRating source ↗ | 35 pints/dayRating source ↗ |
| Capacity at 73°F / 60% RH | Not established at this condition | 42 pints/dayRating source ↗ |
| Capacity at 80°F / 60% RH | 70 pints/dayRating source ↗ | 50 pints/dayRating source ↗ |
| A question to resolve | This record covers part 4044110 and manual TS-2081, April 2026 Revision C. Older part 4033600 uses different refrigerant and performance evidence.All ordering questions → | Specification Form 1033, September 2025, includes the interface in cabinet width and excludes adjustable feet from height. The drawing gives 11.70-inch width, 9.90-inch body height and 24.83-inch length; feet adjust from 0.38 to 2 inches.All ordering questions → |
Amazon listings
Confirm the selected model, revision and included accessories before ordering.
Sylvane listings
Confirm the selected model, revision and included accessories before ordering.
Check your proposed configuration.
Record space, operating conditions and drainage before treating any specification as an installation decision.
Open the constraint worksheet →How rating conditions affect comparison →