AprilAire E070W

Capacity at 80°F / 60% RH70pints / day
Cabinet height12.5inches, cabinet only
Drainagegravity by default; optional 4856 pump

Allow separately for feet, accessories, airflow and service access.

4 items to confirm before ordering

Confirm the selected model, revision and included accessories before ordering.

View on Amazon

This link opens the "Wi-Fi Enabled" option, model E070W, on Sylvane's E070 page. Check that this option is still selected before ordering.

View at Sylvane

Sources checked 2026-11-11 · Documentary comparison

Capacity at stated conditions

Keep temperature and humidity beside the number. Published points are not a prediction for your crawlspace.

Published water removal; no temperature conversion
TemperatureHumidityPints / dayEvidence
80°F60% RH70Source ↗
73°F60% RH53Source ↗
How to compare capacity ratings

Specifications that shape the installation

Exact model / part
E070W
Cabinet height × width × length
12.5 × 12.5 × 25 inCabinet only. Add accessories, airflow and service access.
Drainage configuration
gravity by default; optional 4856 pump
Documented inlet range
50 to 104°FRange source ↗
AprilAire also specifies a 40°F minimum dew point. Inlet temperature alone does not qualify operating conditions.

Accessories to confirm

Check the exact part and inclusion with the supplier before budgeting for installation.

pump

Part 4856 · Confirm inclusion with supplier

Source ↗

hanging kit

Part 5822 · Confirm inclusion with supplier

Source ↗
Budget for the complete configuration

Keep these questions on your checklist

  1. Specification Form 1013, July 2025, excludes filter doors from width, duct collars from length and feet from height.

  2. The drawing gives 24.84-inch cabinet length and 32.84 inches with both collars. Each collar adds four inches. Allow separately for duct bends and service access.

  3. The inspected specification gives 53 pints/day at 73°F and 60% RH, with no 65°F point. No generic conversion is applied.

  4. Dehumidification requires 50 to 104°F inlet air and at least a 40°F dew point. The complete service-clearance envelope remains unconfirmed.

Match the manual, accessories and actual equipment revision to your proposed installation. We have not tested this model hands-on.

Sources for this model

01AprilAire E070W product documentationAprilAire
Document date
Not established
Checked
2026-11-11
Open source document ↗
02AprilAire E050W, E070W, E080W, E100W and E130W installation and owner’s manualAprilAire
Document date
Not established
Checked
2026-11-11
Open source document ↗
03AprilAire E070W specification sheetAprilAire
Document date
July 2025
Revision
Form No. 1013 · 325436 · 07.25
Checked
2026-11-11
Open source document ↗
04AprilAire E070W product documentationAprilAire
Document date
Not established
Checked
2026-11-11
Open source document ↗