Compare dehumidifier ratings at the same conditions
A capacity comparison needs the same temperature and relative humidity on both sides. Keep every published rating point intact.

On this page
Compare one model at two documented points
| Santa Fe Compact70 | Temperature | Relative humidity | Removal |
|---|---|---|---|
| Warmer test point | 80°F | 60% | 70 pints/day |
| Cooler test point | 65°F | 60% | 43.7 pints/day |
Both rows describe the same model. Keep the conditions beside the number when comparing another unit.
Choose the comparison condition
Choose one temperature and relative humidity before comparing models. The warmer point in the table cannot establish removal in a cooler crawlspace.
The Oasis105 documents 67 pints/day at 65°F and 60% RH. The E050W specification lists 35 at that condition. These numbers support a capacity comparison at that point; they leave installation and the building's actual moisture load unresolved.
Keep missing ratings missing
The E070W specification lists 53 pints/day at 73°F and 60% RH. The inspected specification does not supply a 65°F point. Applying a generic conversion would introduce a number the source never stated.
Record the duty separately
A stipulated 60 pints/day duty at 65°F and 60% RH is useful for checking arithmetic against a published point. It does not mean your crawlspace needs that duty. Ask the person assessing the building to state the required removal and conditions.
Use the constraint worksheet to compare a specified duty with the available points. Read the methodology for how missing values affect results.
Sources and limitations
Santa Fe Compact70 product documentation Checked 2026-11-11
Santa Fe · Document date: not established · Primary source
Product specifications
Unit Dimensions 12"W x 12"H x 21"D
Product specifications
65°F and 60% RH Water Removal 43.7 Pints/Day
Product specifications
70 Pints
Product specifications
8.75 Gallons @ 80°F and 60% RH
Product specifications
4044110
Documentary evidence for the named model and revision. Checked date records retrieval. Each excerpt identifies its section or page; drawing transcriptions are labelled separately.
Santa Fe Oasis105 product documentation Checked 2026-11-11
Santa Fe · Document date: not established · Primary source
Product specifications
Unit Dimensions 24"W x 14.5"H x 16"D
Product specifications
65°F and 60% RH Water Removal 67 Pints/Day
Documentary evidence for the named model and revision. Checked date records retrieval. Each excerpt identifies its section or page; drawing transcriptions are labelled separately.
AprilAire E050W specification sheet Checked 2026-11-11
AprilAire · Document date: September 2025 · Primary source
Document revision: Form No. 1033 · 326654 · 09.25
Page 1, specifications and footnotes
@ 65°F/60% RH 35 ppd
Page 1, specifications and footnotes
Height does not include adjustable feet. The width Includes the User Interface.
Page 1, specifications and footnotes
@ 80°F/60% RH 50 ppd
Page 1, specifications and footnotes
@ 73°F/60% RH 42 ppd
Page 2, accessory section heading
Optional Accessories
Page 2, optional condensate pump
Model 4856
Page 2, Model 4856
Condensate Pump
Page 2, Model 4856
22 ft. lift
Page 2, dimension drawing · Diagram transcription
11.70-inch body width; 9.90-inch body height; 24.83-inch length; feet adjust from 0.38 to 2.00 inches.
Page 2, optional duct collar kit
Model 70000047
Page 2, Model 70000047
Duct Collar Kit
Documentary evidence for the named model and revision. Checked date records retrieval. Each excerpt identifies its section or page; drawing transcriptions are labelled separately.
AprilAire E070W specification sheet Checked 2026-11-11
AprilAire · Document date: July 2025 · Primary source
Document revision: Form No. 1013 · 325436 · 07.25
Page 1, specifications and footnotes
@ 73°F/60% RH 53 ppd
Page 1, specifications and footnotes
@ 80°F/60% RH 70 ppd
Page 2, accessory section heading
Optional Accessories
Page 2, optional condensate pump
Model 4856
Page 2, Model 4856
Condensate Pump
Page 2, Model 4856
22 ft. lift
Page 1, footnote 2 (continues in next excerpt)
Height does not include adjustable feet. The width excludes the filter doors and length
Page 1, continuation of footnote 2
excludes the duct collars.
Page 2, upper side-view drawing · Diagram transcription
32.84 inches across both collars; 24.84 inches across the cabinet; each collar extends 4.00 inches.
Documentary evidence for the named model and revision. Checked date records retrieval. Each excerpt identifies its section or page; drawing transcriptions are labelled separately.
Documentary comparison. Confirm the exact model, configuration and installation requirements before ordering.